Installation Instructions for 6A-A1C six bolt Composite
Disc Couplings
1. Tools Required:
Torque wrench with hex sockets for clamp hub
socket head cap screws.
Laser alignment tool or dial indicator
(recommended). If not available a straight edge
and feeler gauges.
Caliper
2. These instructions are for standard series couplings
with normal running conditions. Special couplings may
have different instructions or drawings.
3. When initially mounting the coupling, the
misalignment may be one and one half times the
maximum permissible misalignment shown in the
catalog. Inspect hub bores, shafts, and keyways
making sure there are no burrs. Clean hub bores and
shafts. Standard CD coupling hubs are supplied with
slight clearance fit (see catalog).
6A A1C Six Bolt Composite
Disc
Coupling
Note: Aligning the shafts as closely as possible at the
time of initial installation will reduce noise and allow the
coupling extra capacity for misalignments and loads
which will occur during operation over the life of the
connected equipment. Installing and operating coupling
at higher degrees of misalignment is possible (see
catalog ratings), but will generally reduce the life of the
composite disc pack.
5. Adjust hub separation to dimension “C” specified in
the Table and diagram. Tighten Second hub to the shaft.
6. Align the shafts within the limits for parallel and
angular misalignment specified on page two. For best
alignment results, use a laser alignment tool or dial
indicator.
Coupling and shaft alignment should be checked
periodically due to foundation settling, equipment
shifting, etc. Alignment should be re-checked after the
first several hours of operation.
Caution: Rotating equipment is potentially
dangerous and should be properly guarded. It is the
responsibility of the machine builder, user, or operator
to follow all applicable safety codes and provide a
suitable guard. Make sure the machine is “locked out”
and cannot be accidently started during installation or
maintenance of coupling.
6A-A1C-0924-1
4. Install the coupling onto the shafts. It is recommended
that the ends of both shafts be flush with the end of
each hub. At the minimum each shaft should extend
past the hub clamp slot and extend into one third of the
hub flange (non-slotted) area. If the shaft extends past
the hub face verify there is enough clearance between
shaft and disc pack and the shaft will not contact the
disc pack during operation. Tighten one clamp hub
socket head cap screw to lock the hub onto the shaft.
See the table for the proper tightening torque.
13200 Sixth Avenue North Plymouth, MN 55441-5509 PHONE (763) 546-4300 FAX (763) 546-8260
TOLL FREE 1-800-533-1731 www.zero-max.com
6A SINGLE FLEX
Page view 0
1 2

Summary of Contents

Page 1 - 6A SINGLE FLEX

Installation Instructions for 6A-A1C six bolt Composite Disc Couplings 1. Tools Required:  Torque wrench with hex sockets for cl

Page 2 - Coupling

6A A1C Six Bolt Composite Disc Coupling 6A-A1C-0924-1 13200 Sixth Avenue North Plymouth, MN 55441-5509 PHONE (763) 546-4300 FAX (763) 546-8260

Comments to this Manuals

No comments